Spec insulation 1: Interior wall spray foam insulation - London SE16
Structural concrete wall surface was very cold, and mouldy behind the cupboard. This located between bedroom and public opened staircase.
- Surface preparation
- Galvanised steel frame studwork instalation
- Spraying (closed sell PUR foam)
- Plasterboarding
- Skimming (surface preparation for paint)
- Painting
Spec insulation 2: Window sill spray foam insulation - London TW10
Timber frame window sill studwork insulation was not satisfied. Interior sill surface was cold, wet.
- Opening existing sill
- Galvanised steel frame studwork instalation
- Spraying (closed sell PUR foam)
- Trimming the surface
- Close down exterior facede
- Coating
Spec insulation 3: Party wall spray foam insulation - London SE7
Project: Garage conversion, new room going to be utility room. The partywall could be insulated only interior side.
- Building timber frame structural studwork
- Cleaning existing cold brick surface
- Wiring (new sockets)
- Spraying (closed cell PUR foam)
- Trimming the surface
- Plasterboarding
- Skimming to prepare painting